Chapter 6 - Performing System Upgrades Landis+Gyr
70 98-1031 Rev AA Concentrator User and Installation Guide
G. Type bye.
Figure 6 - 23. C:\bye
6. Boot to Diagnostics Mode by typing y for yes in the Hyperterminal window.
7. When the command prompt displays a message to say the transfer is complete, type bye to reset
the board.
8. Return to Hyperterminal. Type y for Yes to return to the Diagnostics menu.
9. Confirm the subnet mask address.
Figure 6 - 24. Ramlog read successful message
After a few seconds, Hyperterminal displays messages to confirm a successful
restart. When you see the message “Ramlog Read Successful,” you can
continue with the programming process.
Return to Diagnostics quickly, or Hyperterminal tries to obtain another new IP
address.