Landis+Gyr Chapter 8 - Dresser Roots Installation
Installation Guide 98-1135 Rev AB 107
Figure 8 - 18. Main Board Reed Switch Location
Field Programming and Data Collection
Field programming and data collection will be done with the Endpoint Testing Manager tool. Please
refer to the Endpoint Testing Manager User Guide, publication 98-1055.
Battery Change Out
When the battery flag (R) is set, it could be due to:
A single end-point occurrence, where the end-point may require more current to operate. In
this case, a battery in a single endpoint needs to be replaced.
Occurrence on several end-points, where a battery change out program needs to be
implemented within the following year.
The flag being set during the coldest part of the day, where the battery may have less than
20% of energy left (2-4 years of service time remaining).
Occurrence more often even during the daylight hours. In this case, the battery has even less
energy remaining (1-2 years of service time remaining).
To Change Out The Battery
1. Hold a magnet on the magnetic reed switch (about 20 seconds) until the LED flashes one time.
This indicates that the module has been put in sleep mode.