User Manual

Table Of Contents
Chapter 8 - Dresser Roots Installation Landis+Gyr
110 98-1135 Rev AB Installation Guide
Figure 8 - 21. 02085 - CRC Di-Electric Grease, Silicone
Novagard® G661 and Dow 4 Insulating Sealant can be used as a sealant to prevent water intrusion
into the battery circuit board connections.
1. Liberally apply CRC Di-Electric Grease Compound, the compound, to the Battery Circuit Board
Connector.
U WARNING: Use of other sealants will void any warranty.
Figure 8 - 22. Apply the Compound to the Battery Connector
2. Force the compound between the connector pins with a cotton tipped swab or other suitable
applicator as shown in the next figure.
Figure 8 - 23. Force the Compound Between Connector Pins
3. Liberally apply the compound to the Battery Interface Cable connector. Use a cotton tipped
swab or other suitable applicator to force the compound into ALL holes and cover ALL
electrical contacts.