Landis+Gyr Appendix A - GPR Waterproofing
Installation Guide 98-1135 Rev AB 115
3. Liberally apply the compound to the connectors of the GPR Pulse Input and Battery Interface
cables. Force the compound into ALL holes and cover ALL electrical contacts, as shown in the
following photos.
NOTE: The following photos show representative cables to illustrate compound application.
Figure A - 5. Apply the Compound to GPR Cable Connectors: Cover All Contacts
4. First, install the GPR Pulse Input cable, and then the Battery Interface cable, onto the GPR
circuit board connectors as shown in Figure A - 6.
U WARNING: The GPR Pulse Input cable MUST be installed prior to installing the Battery cable.
Do NOT disconnect the Battery cable after it has been installed. Disconnecting the battery
may cause unwanted pulses to be counted by the GPR. If the battery is disconnected,
reprogram the GPR to clear any unwanted pulse counts, then reconnect the battery.
U WARNING: Substitution of components may impair the suitability for Class I, Division 1
applications. Replace battery only with Landis+Gyr part number 40-1235.
5. Liberally apply the compound to the back of each cable connector, forcing the compound into
each hole where the wires exit the connectors. The GPR circuit board and cable connectors must
be completely covered as shown in Figure A - 6. A cotton tipped swab may be used to force the
compound between each wire and into each connector hole.
NOTE: Battery should not be connected until GPR is fully mounted.