Installation Guide 98-1135 Rev AB 33
Figure 3 - 5. Cover Gasket and Base Plate with Optional Tamper Cup & Seal
Figure 3 - 6. Commercial Module Cover Removed
4. Swipe each end of the module with an RF Buster or magnet to force the module to save meter
data to non-volatile memory. Remove the Commercial Gas Module tamper seals, screws, and
cover. Disconnect the battery.
5. The Commercial Gas Module must be disassociated from the meter.
6. Disconnect the module from the programming device. Leave the battery disconnected, replace
the module cover, and return the module to the Landis+Gyr cross-dock.
American Mini Switch Kit Installation
Meter Preparation
1. Remove the tamper seals and screws from the index cover as shown in the following photos.