42 98-1135 Rev AB Installation Guide
GPR Mounting
1. Using two #12-24 x 1/2 inch screws (part# 22-0185), install the GPR Mini Switch cover
assembly as shown in the following photographs.
A CAUTION: Check the index cover switch cable assembly for nicks, abrasions, or any damage
prior to installing the assembly onto the meter.
2. Install a new index cover gasket as required. Tighten the screws to 20 inch-pounds (± 5 inch-
pounds.
Figure 3 - 26. Tighten Front and Rear Cover Screws to 20 in-lbs (± 5 in-lbs)
U WARNING: Take care not to pinch the index cover switch cable assembly in any way,
especially during the following installation steps:
During index cover and cable assembly installation onto the meter.
During GPR enclosure cover installation.
Between the GPR and meter brackets and meter.
3. Install front and rear index cover tamper seals.
4. Coil the excess cable. Route it behind the index cover and dress it beneath the GPR bracket.
Figure 3 - 27. GPR at C enter Rear - Using 28-1441Bracket
5. Secure the cable to the bracket immediately below the GPR housing with a black nylon zip tie as