Chapter 4 - Rockwell GPR Index Cover & GPR Install Landis+Gyr
48 98-1135 Rev AB Installation Guide
Figure 4 - 3. Center Dial and Offset Dial Mount Rockwell Commercial Index Covers
NOTE: There are two types of Rockwell Commercial index covers. Shown at left in Figure 4 - 3 is
the Center Dial Mount and at right is the Offset Dial Mount. Both types may be removed from the
meter in the same manner as shown in the next illustration.
Figure 4 - 4. Remove Module Bracket Tamper Seals, Screws, and Gas Module Assembly
3. Remove the 5/16-18 x 3/8-inch index frame screws and index mounting frame assembly from
the meter. Set the screws aside for later use.
A CAUTION: DO NOT remove the index from the mounting frame unless the frame or index is
damaged.
For proper meter operation, the frame screw tabs should be approximately 90 degrees
(perpendicular) to the upper portion of the frame containing the index.
Figure 4 - 5. Index Frame Screws and Frame Tabs