User Manual

Table Of Contents
Landis+Gyr Chapter 4 - Rockwell GPR Index Cover & GPR Install
Installation Guide 98-1135 Rev AB 53
GPR Direction
The GPR must face away from nearby walls and should be installed in a location unobstructed by
gas pipes. Refer to "Rockwell Changing GPR Orientation" on page -55 for instructions. Refer to
Appendix A
, GPR Waterproofing for waterproofing guidelines before attaching connectors. Photos
are for reference only: GPR cover and battery should not be connected until Chapter 2.
U WARNING: The GPR and bracket must not interfere with access to the meter pressure tap.
There must be adequate room for connections to the pressure tap (refer to the following
photo).
Figure 4 - 13. Meter Pressure Tap
GPR Mounting
A CAUTION: Check the index cover switch cable assembly for nicks, abrasions, or any damage
prior to installing the assembly onto the meter.
1. Install the GPR bracket onto the index cover so that the bracket slot straddles the cable strain
relief as shown in Figure 4 - 14.
2. Use the two 5/16-18 x 1.25" screws and tamper cups provided in the parts kit to attach the GPR
bracket onto the index cover as shown in Figure 4 - 14. Tighten the screws to between 15 and 20
inch-pounds, as shown in Figure 4 - 15.
Figure 4 - 14. Install GPR Bracket, Screws and Tamper Cups
3. Install tamper seals into the tamper cups as shown in Figure 4 - 17 and Figure 4 - 16.