Chapter 4 - Rockwell GPR Index Cover & GPR Install Landis+Gyr
54 98-1135 Rev AB Installation Guide
Figure 4 - 15. Tighten Bracket Screws 15 to 20 inch-pounds
NOTE: Sensus (Rockwell/Equimeter) does not specify nor recommend a gasket between the index
cover and meter head. The meter parts list and assembly diagram do not include an index cover
gasket.
U WARNING: Take care not to pinch the index cover switch cable assembly in any way,
especially during the following installation steps:
during index cover and cable assembly installation onto the meter.
during GPR enclosure cover installation.
between the GPR and meter brackets and meter.
Figure 4 - 16. Coil Excess Cable
4. Coil the excess cable as shown in the photographs above.
5. Route the cable behind the index cover and dress it beneath the GPR bracket as shown in the
previous photo. Take care not to crimp the cable or pull the cable tight.
6. Secure the coiled cable to the GPR bracket with a black nylon zip tie.