Chapter 6 - Sprague GPR Index Cover & GPR Install Landis+Gyr
78 98-1135 Rev AB Installation Guide
Figure 6 - 21. Switch Wires Must Not Interfere With Index Pointers
5. Route the cable between the GPR bracket and top of the meter so that the cable has minimal
slack protruding from behind the bracket. Verify that the cable is not pinched between the
bracket and meter.
If the cable will not fit beneath the GPR bracket, or if the cable is subject to pinching or abrasion
between bracket and meter, attach the excess coiled cable to the top of the index cover bracket,
immediately below the GPR as shown in the next figure.
Figure 6 - 22. Cable Optionally Routed Above Index Cover Bracket
6. Tighten the nylon zip tie so that the cable is snug against the bracket. Cut away excess tie length.
7. Install the two 10-24 x 3/4 inch index cover screws with flat washers. Install one at lower left
and the other at upper right. Do not tighten these screws.
8. Install two tamper cups, plastic washers, and 10-24 x 7/8 inch screws in the remaining cover
holes. Tighten all four cover screws to a torque value of 20 inch-pounds.