Installation Guide 98-1135 Rev AB 85
Electronic Pulser Installation
GPR Mounting
The GPR module will be mounted vertically and upright, on a pipe-mounting bracket in proximity to
the pulse output of the gas meter, to minimize the cable length. This bracket can accommodate pipe
diameters in the range of 2" to 3". Optionally, the GPR can be mounted on a nearby vertical surface.
The cable will be routed in order to minimize its exposure to possible damage. Figure 1 below shows
a typical installation.
Figure 7 - 1. GPR Mounting Examples
Installation Instructions for Outdoor Meters
1. Find a mounting location on a pipe near the pulse output of the meter. Attach the GPR enclosure
to the mounting bracket as shown in the following figures.
NOTE: The GPR must face away from nearby walls and should be installed in a location
unobstructed by gas pipes.
A. Determine whether the GPR is to be installed on a horizontal or vertical pipe.
Figure 7 - 4 shows an example bracket orientation for horizontal pipe installations.
Figure 7 - 5 shows an example bracket orientation for vertical pipe installations.
B. Attach the GPR enclosure to the L-shaped bracket through the smaller holes with four 6-20
x ½ inch security Torx screws from the GPR Pipe Mounting Kit (45-0080).
NOTE: The GPR must be installed on the bracket with the cable entry notch located at the