Chapter 7 - Electronic Pulser Installation Landis+Gyr
88 98-1135 Rev AB Installation Guide
Figure 7 - 5. GPR/Bracket Assembly for Vertical Pipe Installation
3. Select the appropriate cable for the meter model and pulser type onto which the GPR is to be
installed.
Refer to the individual meter model and pulser type sections below for information on
cable selection.
4. Route the signal transmission cable along the most direct and convenient route between the
Meter and the GPR (preferably along the pipe). Secure the transmission cable to the pipe with
black nylon UV-rated tie wraps in locations along the pipe 12" apart.
5. Connect the cable to meter\pulser.
Refer to the individual meter model and pulser type sections that follow.
Refer to the instructions in the following sections on circular Military Style (MS) connectors
and cable splicing and crimping.
U WARNING: Refer to the meter and pulser manufacturers' instructions and warnings on
electrical wiring and electrostatic discharge. Local electrical codes must be followed when
wiring AMR devices in a gas metering environment.
Electronic Pulser Installation
Electronic pulsers include electronic rotary meters and electronic volume correctors (EVC). Typical
electronic pulsers have configurable pulse output channels. An output channel may be configured for