Landis+Gyr Chapter 7 - Electronic Pulser Installation
Installation Guide 98-1135 Rev AB 91
Figure 7 - 7. GPR Module Interior
Interface to a Single Form-A Volume Output
For a single Form-A volume pulse output, connect the pulser to Chan B of the GPR using the
recommended cable 19-2330. The installation procedure is as follows.
1. Refer to the user manual of the pulser for information on its pulse outputs interface. The pulse
output interface on the pulser may be a terminal block or flying leads. A terminal on the terminal
block is usually labeled K, Y, or Z.
2. Connect the DRAIN lead to the drain terminal on the pulser output connector. The drain
connection is optional.
3. Connect both the CHAN B NO and CHAN B TAMPER TEST leads to the Y terminal on the
pulser output connector.
4. Connect the CHAN B COM lead to the K terminal on the pulser output connector.
5. Apply Di-Electric Grease Compound to the sensor connector.
6. Connect the cable connector to the GPR sensor connector. Make sure the cable connector is
correctly mated to the pins on the GPR sensor connector, otherwise the GPR will not detect
pulses. See the figures and table below. Make sure pin #5 on the cable connector is mated to pin
#5 on the sensor connector.
Battery Connection
GPR Sensor Connector Pin #1