User Manual

Table Of Contents
Landis+Gyr Chapter 7 - Electronic Pulser Installation
Installation Guide 98-1135 Rev AB 93
Figure 7 - 9. Cable to GPR Connection for a Single Form-A Volume Input
NOTE: Battery should not be connected until GPR is fully mounted.
Interface to Mil-Spec Circular Connector
For pulsers that have one or two Form-A outputs through a Mil-Spec circular connector, the
recommended cable for use is 19-2332. The installation procedure is as follows.
1. Refer to the pulse outputs section of the pulser's installation manual and check to make sure the
signal interface corresponds to the definitions shown in the table below.
2. Connect the male circular connector on the cable to the pulse output connector on the pulser.
3. Apply Di-Electric Grease Compound to the sensor connector. See Appendix A
, GPR
Waterproofing for more information.
4. Connect the cable connector to the GPR sensor connector.