User Manual

Table Of Contents
Chapter 7 - Electronic Pulser Installation Landis+Gyr
94 98-1135 Rev AB Installation Guide
Figure 7 - 10. Circular Connector Wiring for Two Form-A Volume Inputs
NOTE: The cable connector is shown downside up.
Table 7 - 3. Two Form-A Volume Inputs Wiring Definitions
GPR 19-2332 Cable Pulser Output Connector
GPR Sensor
Connector Pin #
Signal and Description Lead Color
Circular Connector
Pin Label
Description
1
CHAN A NO, channel A
normally open
ORANGE A Normally Open
2
CHAN A COM, Channel
A common
WHITE/ORANGE B Common
3 N/C N/A N/A Not Applicable
4
CHAN A TAMPER TEST,
Channel A tamper test
WHITE/GREEN A Normally Open
5 Ground Drain C Drain
6
CHAN B NO, Channel B
normally open
BLUE D Normally Open
7
CHAN B COM, Channel
B common
WHITE/BLUE E Common