Landis+Gyr Chapter 7 - Electronic Pulser Installation
Installation Guide 98-1135 Rev AB 95
Interface to Multi-Outputs
The cable 19-2331 can be used for multi-output interfaces such as conduit, cable gland, or terminal
block. This cable supports only Form-A volume outputs.
The general installation procedure is as follows.
1. Refer to the pulse outputs section of the pulser's installation manual.
2. Connect the DRAIN lead to the drain terminal on the pulser output connector. The drain
connection is optional.
3. Make connection to the volume pulse output channels and alarm channel according to the table
below.
4. Apply Di-Electric Grease Compound to the sensor connector. See Appendix A
, GPR
Waterproofing for more information.
5. Connect the cable connector to the GPR sensor connector.
8 N/C N/A N/A Not Applicable
9
CHAN B TAMPER TEST,
channel B tamper test
GREEN D Normally Open
10 N/C N/A N/A Not Applicable
11 N/C N/A N/A Not Applicable
Table 7 - 3. Two Form-A Volume Inputs Wiring Definitions
GPR 19-2332 Cable Pulser Output Connector
GPR Sensor
Connector Pin #
Signal and Description Lead Color
Circular Connector
Pin Label
Description