2Pressandhold thebuttonontheRFBuster.PositiontheRFBusterlessthan
sixinchesawayfromtheleftsideoftheCPR.TheRFBustermakesaudible
beepsandtheLEDflashestoconfirmtransmissionoftheRFpacketsfromthe
endpoint.
3IftheRFBusterdetectspacketswithinonemi
n
ute,theinstallationisgood.If
theRFBusterdoesnotbeep,refertoʺTroubleshootingʺonpage 79.
4 Attachthecoverusingthefourscrewsincludedinthehardwarekit.
5Cleantheareaandremovealldisposablematerials.
ENDPOINT REPLACEMENT
Pleasefollowtheinstructionsbelowtoreplaceanendpoint:
1OpenthefaceoftheCPR.
2Writedownthecolortranslation.
3Carefullycutanytiewraps.
4CutoffScotchloksnearthecrimp.
5 UnmounttheCPR.
6 Disconnectthebattery.
ProceedtoʺConnectingthePRECOSwitchtotheCPRʺonpage 75.
TROUBLESHOOTING
RF Buster Does Not Beep When Testing
1First,verifythatthebatteryisproperlyconnected,redwiretoredwire.
2DoestheRFBusterbeepandlighttheLEDwhentheswitchisinitially
pressed?Ifnot,thebatteryintheRFBusterisdead.ReplacetheRFBuster
battery,oruseanotherRFBuster.
3Afteractivatingthemagneticswit chon
theCPR,holdtheRFBusterswitch
oncontinuously.PointtheLEDendoftheRFBustertowardthefrontofthe
CPR.HoldtheRFBusterbetween6”and12”fromthefrontoftheCPR.Wait
tenseconds.IftheRFBusterdoesnotbeep,replacetheCPRb
attery.
Customer Support
ToreachCustomerSupportatCellnet:
Email:customersupport@cellnet.com
Telephone:18007912567.
Hoursofoperation‐8:00a.m.ETto5:00p.m.ET
Do not use a cell phone or any other RF device while conducting