Certification Exhibit FCC ID: R7PSSMM2TRP FCC Rule Part: 15.247 ACS Project Number: 11-0444 Manufacturer: Landis+Gyr Technology, Inc. Model: L+G Solid State Meter Module Manual 5015 B.U.
12 Landis+Gyr Solid State Meter Module Quick Start Guide D ra ft 12 /7 /2 0 Publication: 98-1284 Rev AA LANDIS+GYR CONFIDENTIAL INFORMATION
Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr.
Solid State Meter Module Quick Start Guide Overview D ra ft 12 /7 /2 0 12 The Landis+Gyr Solid State Meter Module (SSMM) is designed to provide active energy (Kilo-Watt hour) data from Landis+Gyr S4e meters for use in residential and industrial commercial services. Figure 1 - 1.
Solid State Meter Module Quick Start Guide Landis+Gyr Required Software To work with the endpoint, you need at least one of the following software tools and documentation: • UtiliNet Solution Center (USC) • Meter Master Lite software • • Meter Master Lite Quick Start Guide, publication number 98-0071 Landis+Gyr 1132Prog\1132Com software Landis+Gyr recommends you have RF Verify software and the RF Verify User Guide, publication number 98-0069.
Landis+Gyr Solid State Meter Module Quick Start Guide LAN ID The LAN ID is a unique identifier for each Landis+Gyr endpoint. Landis+Gyr provides the LAN address. You cannot change the LAN ID of a radio. Features and Functions Endpoint Registration The endpoint is automatically registered with the host system. No special tools are needed during installation.
Solid State Meter Module Quick Start Guide • Total count • Last ten interval counts Landis+Gyr Customer Service Contact Landis+Gyr Customer Support at solutionsupport.na@landisgyr.com or call 888-390-5733 with any questions or problems for guidance through the troubleshooting process. Compliance 12 FCC Class B This device complies with Part 15 of the FCC rules.
Landis+Gyr Solid State Meter Module Quick Start Guide This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and D ra ft 12 /7 /2 0 12 (2) This device must accept any interference received, including interference that may cause undesired operation.
Solid State Meter Module Quick Start Guide Landis+Gyr Product Specifications Table 3. Landis+Gyr Solid State Meter Module Specifications Value or Range Specification Landis+Gyr Supported Meter Forms Compatible Meters NOTE: Contact Landis+Gyr for additional forms.
Landis+Gyr Solid State Meter Module Quick Start Guide Table 3. Landis+Gyr Solid State Meter Module Specifications(Continued) Standards Compliance Specification Value or Range FCC Title 47 CFR Part 15 Subpart B & C Radiated and Conducted Emissions IEC 61000 4-2,3,4,5 Electromagnetic Compatibility ANSI C12.1-2011 Electricity Metering ANSI C12.20-2002 Electricity Meters Standard ANSI C37.90.