8: Line and Tunnel Settings
EDS1100/2100 User Guide 50
Figure 8-10 Tunnel 1 Packing Mode (Timeout)
3. Enter or modify the fields in Table 8-11.
4. Click Submit.
5. Click Send Character. Figure 8-12 shows the page that displays.
Table 8-11 Tunnel Packing Mode (Timeout) Fields
Field Description
Threshold Send the queued data when the number of queued bytes reaches the
threshold.
Timeout Enter a time, in milliseconds, for the EDS1100/2100 to send the queued data
after the first character was received.