3: Installation of PremierWave XC HSPA+
PremierWave XC HSPA+ User Guide 23
Back Panel
On the PremierWave is a Power 1 Plug and RJ-45 Ethernet port as shown in Table 3-9.
Table 3-9 PremierWave Bottom/Back Panel View
Table 3-10 PremierWave XC HSPA+ Connections (Side)
Installing the PremierWave XC HSPA+
The device comes with brackets for mounting it, for example, on a wall. If using AC power, do not
use outlets controlled by a wall switch.
Observe the following guidelines when connecting the devices:
The PremierWave serial ports support RS-232/422/485.
Use a null modem cable to connect the serial port to another DTE device. Use a straight-
though (modem) cable to connect the serial port to a DCE device.
Connect your RJ-45 Ethernet cable to the RJ-45 port of the unit.
The PremierWave supports a power range of 9 to 30 VDC.
Note: As soon as you plug the device into power, the device powers up automatically,
the self-test begins, and LEDs would indicate the device's status
Connector Description
Relay Output Outputs Support 1A 24V
Inputs Inputs accept voltage 0 to 30 VDC.
ON Max 30 VDC
Min 2 VDC
OFF Max 0.7 VDC
Min 0 VDC
Antenna Ethernet Terminal Block Barrel Antenna
(RX Diversity) Power (6-pin) Plug
Power
Relay IN2 IN1
Relay CM2 CM1