9: Line and Tunnel Settings
PremierWave XC HSPA+ User Guide 55
Relay Output
Note: When relay is energized/turned on, the relay is closed connecting both relay ports
on the IO connector through the relay. When the relay is turned off, the signal path is
open, disconnecting the relay ports on the IO connector.
Table 9-9 Relay Output Settings
To Configure Relay Settings
Using Web Manager
To configure relay output, go to the Setup tab/page and click Relay > Relay 1 >
Configuration in the menu.
Using the CLI
To enter the relay command level: enable -> config -> relays -> relay
<number>
Using XML
Include in your file: <configgroup name="relay" instance="<number">
Input Settings Description
State Select On or Off whether to display the configuration and status for the Relays.
Title Enter the relay title as it will appear in web manager, XML and CLI. Leave this field
blank to utilize the default “Relay N”, where N is the relay number. For example, you
can name the reading, “Buzzer”, if a buzzer is connected to the PremierWave device.
Latch Enable or disable Latch controls which determine how a relay will be turned off.
Selecting Enabled will require a user to explicitly reset latched relay and then turn it
off.
Selecting Disabled, the relay will automaticaly turn off after any and all of the alarm
triggers are no longer active.