Product Info

LP
WA Module Series
BG95 Series Hardware Design
BG95_S
eries_Hardware_Design 74 / 106
6.3. Op
erating and Storage Temperatures
The operating and storage temperatures of the module are listed in the following table.
Table 39: Operating and Storage Temperatures
1.
1)
W
ithin operating temperature range, the module meets 3GPP specifications.
2.
2)
W
ithin extended temperature range, the module remains the ability to establish and maintain
functions such as SMS and data transmission, without any unrecoverable malfunction. Radio
spectr
um and radio network are not influenced, while one or more specifications, such as P
ou
t
,
may
exceed the specified tolerances of 3GPP. When the temperature returns to the normal operating
temp
erature levels, the module meets 3GPP specifications again.
6.4. Current Consumption
The f
ollowing table shows current consumption of BG95 series module.
BG95-M4 3.2 3.8 4.2 V
BG95-M
F TBD
3.8 TBD V
I
VB
AT
Pea
k supply
current (during
transmission slot)
Maxi
mum power
control level on
EGSM900
BG95-M3/
BG95-M5
1.8 2.0 A
USB_
VBUS USB detection
BG95
series
5.0 V
Parameter Min. Typ. Max. Unit
Oper
ation Temperature Range
1)
-35 +25 +75 ºC
Extended Temperature Range
2)
-40 +85 ºC
Storag
e Temperature Range -40 +90 ºC
NOTES