User's Manual
Table Of Contents
- Figures
- Tables
- Using This Guide
- Introduction
- Installation and Hardware
- XPress DR+W
- Using DeviceInstaller
- Configuration Using Web Manager
- Configuration Using Telnet or Serial Port (Setup Mode)
- Setup Mode: Server Configuration
- Setup Mode: Channel Configuration
- Channel 1 (Option 1) and Channel 2 (Option 2)
- Baudrate
- I/F (Interface) Mode
- Flow
- Port Number
- Connect Mode
- Send the Escape Sequence (+++) in Modem Mode
- Auto Increment Source Port
- Remote IP Address
- Remote Port
- DisConnMode
- Flush Mode (Buffer Flushing)
- Pack Control
- DisConnTime (Inactivity Timeout)
- Send Characters
- Telnet Terminal Type
- Channel (Port) Password
- WLAN Settings (XPress DR+W Only)
- Setup Mode: Advanced Settings
- Firmware Upgrades
- Monitor Mode
- Troubleshooting and Technical Support
- Technical Specifications
- Lantronix Cables and Adapters
- Alternative Methods of Assigning an IP Address
- Binary to Hexadecimal Conversions
- Compliance Information
- Warranty
Chapter 4: XPress DR+W
XPress DR+ User Guide 40
input style recommended.
Set the Encryption type to the minimum required security. The plus sign denotes that the
group (broadcast) encryption method is different from the pairwise (unicast) encryption, in
this case WEP and TKIP, respectively. For example, CCMP+TKIP => pairwise = CCMP,
and group = TKIP.
WPA2/802.11i
The WPA2/802.11i mode complies with the Robust Secure Network specified in the IEEE
standard 802.11i. It enables the AES-based strong CCMP encryption.
Enter key prompts for the new passphrase. Maximum length is 63 characters; the
recommended minimum is 20 characters.
Set the Encryption type to minimum required security. The plus sign denotes that the
group (broadcast) encryption method is different from the pairwise (unicast) encryption.
For example CCMP+TKIP => pairwise = CCMP, and group = TKIP.
Fixed or Automatic Data Rate
The XPress DR+W can control the transmission rate. Select 0 to set a fixed data rate, or
select 1 to set an automatic data rate. The default setting is 1 (auto).
TX Data rate 0=fixed, 1=auto (1) ? _
Transmission Data Rate
If the above TX Data rate is set to fixed, the selected data rate is the XPress DR+W’s
fixed transmission rate. If the above TX Data rate is set to auto, the selected data rate is
the XPress DR+W’s maximum data rate. Lower data rates allow for larger distances.
They may also be required when communicating with older devices. The default setting is
11 Mbps.
TX Data rate 0=1, 1=2, 2=5.5, 3=11
4=18, 5=24, 6=36, 7=54 Mbps (0) ? _
Note: The unit’s maximum data rate cannot be selected when TX Data rate is set to
auto.
Next Steps
1. Upon completing the IP and WLAN settings, select menu option 9 to save and exit
the XPress DR+W Setup Mode.
2. To configure the XPress DR+W further, continue to Chapter 6: Configuration Using
Web Manager or Chapter 7: Configuration Using Telnet or Serial Port (Setup Mode)