User's Manual
Table Of Contents
- Figures
- Tables
- Using This Guide
- Introduction
- Installation and Hardware
- XPress DR+W
- Using DeviceInstaller
- Configuration Using Web Manager
- Configuration Using Telnet or Serial Port (Setup Mode)
- Setup Mode: Server Configuration
- Setup Mode: Channel Configuration
- Channel 1 (Option 1) and Channel 2 (Option 2)
- Baudrate
- I/F (Interface) Mode
- Flow
- Port Number
- Connect Mode
- Send the Escape Sequence (+++) in Modem Mode
- Auto Increment Source Port
- Remote IP Address
- Remote Port
- DisConnMode
- Flush Mode (Buffer Flushing)
- Pack Control
- DisConnTime (Inactivity Timeout)
- Send Characters
- Telnet Terminal Type
- Channel (Port) Password
- WLAN Settings (XPress DR+W Only)
- Setup Mode: Advanced Settings
- Firmware Upgrades
- Monitor Mode
- Troubleshooting and Technical Support
- Technical Specifications
- Lantronix Cables and Adapters
- Alternative Methods of Assigning an IP Address
- Binary to Hexadecimal Conversions
- Compliance Information
- Warranty
Chapter 5: Using DeviceInstaller
XPress DR+ User Guide 45
Setting Description
Supports Dynamic IP
Non-configurable field. Indicates whether the current IP
address on the XPress DR+ was set manually or assigned
automatically.
DHCP
Non-configurable field that displays only if the unit supports
Dynamic IP. True indicates that the IP address can be
assigned automatically by DHCP.
BOOTP
Non-configurable field that displays only if the unit supports
Dynamic IP. True indicates that the IP address can be
assigned automatically by BOOTP.
RARP
Non-configurable field that displays only if the unit supports
Dynamic IP. True indicates that the IP address can be
assigned automatically by RARP.
Subnet Mask
Non-configurable field. Displays the unit's current subnet
mask. To change the subnet mask, see Assigning an IP
Address on page 42.
Gateway
Non-configurable field. Displays the unit's current gateway. To
change the gateway, see Assigning an IP Address on page
42.
Number of Ports
Non-configurable field. Displays the number of ports on the
XPress DR+.
TCP Keepalive
Non-configurable field. Displays the unit's TCP keepalive
value. The value is in the range 1-65s, and the default setting
is 45.
Supports Configurable
Pins
Non-configurable field. Displays False, indicating configurable
pins are not available on the XPress DR+.
Supports Email Triggers Non-configurable field. Displays False.
Supports AES Data
Stream
Non-configurable field. Displays False.
Supports 485 Non-configurable field. Displays True. XPress DR+ supports
the RS-485 protocol.
Supports 920K Baudrate Non-configurable field. Displays False. XPress DR+ supports
baud rates up to a maximum of 230 Kbaud.
Supports HTTP Server Non-configurable field. Displays True.
Supports HTTP Setup Non-configurable field. Displays True.
Supports 230K Baud
Rate
Non-configurable field. XPress DR+ supports a baud rate of
230 Kbaud. Displays True.
Supports GPIO Non-configurable field. Displays False.