User's Manual
Table Of Contents
- Figures
- Tables
- Using This Guide
- Introduction
- Installation and Hardware
- XPress DR+W
- Using DeviceInstaller
- Configuration Using Web Manager
- Configuration Using Telnet or Serial Port (Setup Mode)
- Setup Mode: Server Configuration
- Setup Mode: Channel Configuration
- Channel 1 (Option 1) and Channel 2 (Option 2)
- Baudrate
- I/F (Interface) Mode
- Flow
- Port Number
- Connect Mode
- Send the Escape Sequence (+++) in Modem Mode
- Auto Increment Source Port
- Remote IP Address
- Remote Port
- DisConnMode
- Flush Mode (Buffer Flushing)
- Pack Control
- DisConnTime (Inactivity Timeout)
- Send Characters
- Telnet Terminal Type
- Channel (Port) Password
- WLAN Settings (XPress DR+W Only)
- Setup Mode: Advanced Settings
- Firmware Upgrades
- Monitor Mode
- Troubleshooting and Technical Support
- Technical Specifications
- Lantronix Cables and Adapters
- Alternative Methods of Assigning an IP Address
- Binary to Hexadecimal Conversions
- Compliance Information
- Warranty
Chapter 9: Setup Mode: Channel Configuration
XPress DR+ User Guide 71
I/F (Interface) Mode
The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation.
I/F Mode (4C) ? _
The following table displays available I/F Mode options.
Note: All bit positions in the table that are blank represent “don’t care” bits for
that particular option, which can be set to either a 0 or 1 value.
Table 9-1. Interface Mode Options
I/F Mode Option 7 6 5 4 3 2 1 0
RS-232C
(1)
0 0
RS-422/485 4-wire 0 1
RS-485 2-wire 1 1
7 Bit 1 0
8 Bit 1 1
No Parity 0 0
Even Parity 1 1
Odd Parity 0 1
1 stop bit 0 1
2 stop bits
(1)
1 1
(1)
2 stop bits are implemented by the software. This might influence performance.
The following table demonstrates how to build some common Interface Mode settings.
Table 9-2. Common Interface Mode Settings
Common I/F Mode Setting Binary Hex
RS-232C, 8-bit, No Parity, 1 stop bit 0100 1100 4C
RS-232C, 7-bit, Even Parity, 1 stop bit 0111 1000 78
RS-485 2-wire, 8-bit, No Parity, 1 stop bit 0100 1111 4F
RS-422, 8-bit, Odd Parity, 1 stop bit 0101 1101 5D
Flow
Flow control sets the local handshaking method for stopping serial input/output.
Flow (0) ? _