Application
ÖLFLEX
®
440 P cables are cold flexible oil-resistant control cables with a core insulation of TPE and an outer sheath of Poly-
urethane for flexible use and fixed installation under increased mechanical load conditions. They are designed for use in dry,
damp and wet conditions. Outdoor use: They may only be installed considering the temperature range.
Continuous busy movements, compulsory guidance respectively usage on cable drums or pulleys or under a strain of more
than 15 N / mm² are not allowed. At room temperature they are widely resistant to certain oils and resistant to acids. The
outer sheath of Polyurethane is resistant against high mechanical load, particularly to abrasion and scouring, cut resistant,
microbe-proof and hydrolysis resistant. All materials used for these cables are halogen-free.
Application range: Construction machinery, machine tools, transfer lines, production plants.
Design
Design based on HD 22.10 S2 resp. VDE 0282-10 and HD 21.13 S1 resp. VDE 0281-13
Approvals up to and inclusive 2,5 mm²: VDE Reg.-No. 6582
Conductor fine wire strands of tinned copper acc. to IEC 60228 resp. VDE 0295, Class 5
Core insulation Thermoplastic elastomer (TPE)
Core identification Black cores with white numbers with or without GN/YE ground conductor
acc. to DIN EN 50334 resp. VDE 0293-334
Outer sheath Polyurethane compound TMPU in acc. to HD 22.10 S2 resp. VDE 0282-10
colour: Silver grey
Electrical properties at 20 °C
Nominal voltage 300 / 500 V
Test voltage 3000 V AC
Mechanical and thermal properties
Min. bending radius occasional flexing: 12,5 x cable diameter
fixed installation: 4 x cable diameter
Temperature range occasional flexing: -40 °C up to +90 °C max. conductor temperature
fixed installation: -50 °C up to +90 °C max. conductor temperature
Flammability flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2
Oil resistance acc. to IEC 60811-2-1 resp. VDE 0473 part 811-2-1
MUD MUD resistant acc. to IEC 61892-4 Annex D
Tests acc. to IEC 60811 resp. VDE 0473 and VDE 0472
EC directive This cable is conform to ECD 2006/95/EC (Low Voltage Directive).