Data Sheet

U.I. Lapp
GmbH
DATA SHEET
ÖLFLEX
®
FD CLASSIC 810 P
DB 0026300
valid from: 10.03.2011
Originator: R. Krämer / PDC
approved: H. Schillinger / PDC
Document: DB0026300EN Page 1 of 1
All rights reserved acc. to DIN ISO 16016.
PD 0019/2.2_11.10EN
Application
ÖLFLEX
FD CLASSIC 810 P cables are oil resistant high-flexible control cables with an outer sheath of Polyurethane for
flexible use and fixed installation subject to medium mechanical stress. They are among others designed for use in dry,
damp or wet rooms. Considering the indicated temperature range an outdoor use is possible. ÖLFLEX
FD CLASSIC 810 P
cables are increased oil resistant and at room temperature widely resistant to acids and caustic solutions. The outer sheath
is resistant against high mechanical stress, particularly to abrasion and scouring, cut resistant, microbe-proof and hydrolysis
resistant. They are especially for use in power chains and in permanently moved machine parts. Usage of these cables in
moving cable carriers or on motor drum guidance or under a tensile strain of more than 15 N/mm
2
conductor cross-section
is not allowed.
Application range:
Machine tools, automation engineering, process measuring and control technology, assembly and handling technique,
transfer lines, assembly lines and production lines.
Design
Design based on HD 21.13 S1 +A1 resp. VDE 0281-13 and HD 22.10 S2 resp. VDE 0282-10
Conductor extra fine wire strands of bare copper acc. to IEC 60228 resp. VDE 0295, Class 6
Core insulation LAPP special PVC compound P8/1, better than the PVC compound TI2,
acc. to HD 21.1 S4 resp. VDE 0281-1
Core identification acc. to VDE 0293-1, with or without GN/YE ground conductor
black cores with white numbers
acc. to DIN EN 50334 resp. VDE 0293 part 334
Outer sheath Polyurethane compound TMPU acc. to EN 50363-10-2 resp. VDE 0207-363-10-2
Colour: Grey, similar RAL 7001
Electrical properties
Nominal voltage U
0
/U: 300/500 V AC
Test voltage C/C: 4000 V AC
Mechanical and thermal properties
Min. bending radius flexing: 7,5 x cable diameter
fixed installation: 4 x cable diameter
Temperature range flexing: - 5 °C up to +70 °C max. conductor temp.
fixed installation: -40 °C up to +80 °C max. conductor temp.
Travel distance in power chains up to 10 m
Oil resistance acc. to EN 50363-10-2 resp. VDE 0207-363-10-2
Flammability flame retardant in acc. with IEC 60332-1-2 resp. VDE 0482-332-1-2
Tests acc. to IEC 60811 resp. VDE 0473 part 811 and VDE 0472
EC-Directives This cable is conform to the EC-Directives 2006/95/EC (Low Voltage Directive)
and 2002/95/EC (RoHS, Restriction of the use of certain hazardous substances).