Datasheet

0034302
DATA SHEET
valid from:
01.01.2019
Creator: PESA / PDC
Released: ALTE / PDC
Document: DB0034302EN
Version: 05
Page 1 of 1
We reserve all rights according to DIN ISO 16016.
PD 0019/05_04.18EN
Application
is a screened data cable for low frequency applications. The cable is designed for fixed installation and for conditional
flexible use. It is used in dry and damp interiors but not appropriate for outside usage.
The screen provides protection against electromagnetic interferences.
The cable is used for example in computer systems, instrumentation technology, office equipment and balances.
Design
Design based on standard VDE 0812
fine wire strands of bare copper wires
special PVC-based compound
according to DIN 47100
cores are stranded in layers,
wrapping with foil on the outer layer
Braiding with tinned copper wires
special PVC-based compound
colour: grey (similar RAL 7032)
dlsafjlöj f
Electrical properties at 20°C
> 20 G Ω x cm
C/C: approx. 120 nF/km
C/S: approx. 160 nF/km
(at 800 Hz)
approx. 0.65 mH/km
0.14 mm²: 350 V (not for power applications)
≥ 0.25 mm²: 500 V (not for power applications)
0.14 mm²: 1200 V
≥ 0.25 mm²: 1500 V
Mechanical and thermal properties
Minimum bending radius
Flexing: 15 x cable Ø
Fixed installation: 6 x cable Ø
Temperature range
Flexing: - 5˚C up to +70˚C
Fixed installation: - 40˚C up to +80˚C
Flammability
flame retardant acc. to IEC 60332-1-2
General requirements
This cable is conform to the EU-Directive 2011/65/EU
(RoHS, Restriction of the use of certain hazardous substances).

Summary of content (1 pages)