Data Sheet

U.I. Lapp
GmbH
DATA SHEET
ÖLFLEX
®
LIFT F
DB 0042020
valid from: 24.09.2010
Originator: R. Krämer / PDC
approved: H. Schillinger / PDC
Document: DB0042020EN page 1 of 1
All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34.
PD 0019/2.1_11.09EN
Application
ÖLFLEX
LIFT F are cold flexible PVC flat cables for flexible use under medium mechanical load conditions. They are among
others designed for use in dry, damp and wet rooms. Outdoor is use temporarily possible, considering the temperature
range. At room temperature they are widely resistant to certain oils and resistant to acids. Continuous operational move-
ments, restricted guidance, usage of these cables in moving cable carriers or on motor drum guidance or under a tensile
strain of more than 15 N / mm² is not allowed.
Application range: Conveyor and hoist equipments, transport installations, supply lines for moving machine parts, indoor
cranes, high rack facilities.
Can be used as elevator control cable up to 35 m suspension length with a maximum travel speed of 1.6 m / sec.
Design
Design based on DIN EN 50214 resp. VDE 0283-2
Conductor acc. to IEC 60228 resp. VDE 0295
≤ 6 mm²: Extra fine wire strands of bare copper, Class 6
≥ 10 mm²: Fine wire strands of bare copper , Class 5
Core insulation PVC compound TI2 acc. to HD 21.1 S4 resp. VDE 0281-1
Core identification acc. to VDE 0293-1, with or without GN/YE ground conductor
up to 5 cores coloured in acc. to HD 308 S2 that is VDE 0293-308
starting at 6 cores: Black cores with white numbers
acc. to DIN EN 50334 resp. VDE 0293-334
Outer sheath up to 1,0 mm²:
PVC compound TM2 acc. to HD 21.1 S4 resp. VDE 0281-1
starting at 1,5 mm²:
PVC compound TM4 (cold flexible) acc. to HD 21.1 S4 resp. VDE 0281-1
Colour: Black
Electrical properties
Nominal voltage up to 1,0 mm²: 300/500 V
starting at 1,5 mm²: 450/750 V
Test voltage 3000 V AC
Mechanical and thermal properties
Min. bending radius flexing: 10 x cable thickness
Temperature range up to 1,0 mm²:
flexing: 0 °C up to +70 °C max. conductor temp.
starting at 1,5 mm²:
flexing: -15 °C up to +70 °C max. conductor temp.
Flammability flame retardant in acc. with IEC 60332-1-2 resp. VDE 0482-332-1-2
Tests acc. to IEC 60811 resp. VDE 0473 and VDE 0472
EC directive This cable is conform to ECD 2006/95/EC (Low Voltage Directive).