Datasheet

0046001
DATA SHEET
valid from:
05.08.2019
Creator: KASC / PDC
Released: ALTE / PDC
Document: DB0046001EN
Version: 06
Page 1 of 1
We reserve all rights according to DIN ISO 16016.
PD 0019/05_04.18EN
Application
d control cables at high ambient temperatures. The use of these
cables is recommended for example in the following fields:
Steel and iron works, cement and ceramic works, foundries, bakery equipment, electric motor industry, sauna and solarium construction,
thermal and heating elements, lighting technology, ventilator engineering, air conditioning technology, oven construction, galvanization
technology and polymer processing.
Design
Design
Conductor
Insulation
Core identification code
Stranding
Outer sheath
dlsafjlöj f
Electrical properties at 20°C
Nominal voltage
300/500 V
Test voltage
core/core: 2000 V
Mechanical and thermal properties
Minimum bending radius
occasional flexing: 15 x cable Ø
fixed installation: 4 x cable Ø
Temperature range
occasional flexing: -25˚C bis +180˚C
(adequate ventilation provided)
fixed installation: -60˚C bis +180˚C
Flammability
flame retardant acc. to IEC 60332-1-2
Halogen free
acc. to IEC 60754-1
Corrosivity of gases
acc. to IEC 60754-2
Tests
acc. to IEC 60811, EN 50395, EN 50396
General requirements
These cables are conform to the EU-Directive 2014/35/EU (Low Voltage Directive)