Data Sheet

U.I. Lapp
GmbH
DATA SHEET
ÖLFLEX
®
CHAIN 809 CY
DB 1026751
valid from: 2014-02-21
Originator: KASC1 / PDC
Approved: HAPF / PDC
Dokument: DB1026751EN
All rights reserved acc. to DIN ISO 16016.
PD 0019/2.2_11.10EN
Application
ÖLFLEX
CHAIN 809 CY cables are high-flexible PVC power and control cables designed for the European, North American
and Canadian market, for flexible use and fixed installation under light or medium mechanical load conditions. They are
among others designed for use in dry, damp or wet rooms. Outdoor use: They may only be installed with UV protection and
considering the indicated temperature range. At room temperature they are widely resistant to acids, caustic solutions and
certain oils. They are especially suitable for basic requirements (Basic Line) in power chains and in permanently moved ma-
chine parts. Usage of these cables in moving cable carriers or on motor drum guidance or under a tensile strain of more
than 15 N/mm
2
conductor cross-section is not allowed. The screen is a protection against electrical interference.
Application range:
Power chains or moving machine parts, measuring, control and regulation circuits, wiring of machines, tools, devices,
appliances and control cabinets.
USE acc. to UL: PVC sheathed cable for external interconnection or internal wiring of electronic equipment.
USE acc. to cRU: Cables for internal wiring or external interconnection with or without mechanical abuse.
This cable is suitable for torsion application in wind turbines (WTG). The torsional load is limited to applications, as they
typically occur in the loop of a wind turbine.
Design
Design acc. to UL AWM Style 20886, CSA C22.2 No. 210-05 and
based on HD 21.13 S1 +A1 resp. VDE 0281-13
Approval UL AWM Style 20886 (File No. E63634)
cRU AWM I A/B, II A/B (File No. E63634)
Conductor fine wire strands of bare copper acc. to IEC 60228 resp. VDE 0295, Class 5
Core insulation PVC compound (UL/CSA 80° C rating)
Core identification acc. to VDE 0293-1, with or without GN/YE ground conductor
black cores with white numbers
acc. to DIN EN 50334 resp. VDE 0293 part 334
Taping non-woven wrapping
Screen braid of tinned copper wires, coverage = 85% (nominal value)
Outer sheath PVC compound (UL/CSA 80° C rating)
Colour: Grey, similar RAL 7001
Electrical properties
Nominal voltage U
0
/U: 300/500 V
UL/CSA: 1000 V
Test voltage Core/Core: 4000 V AC
Core/Screen: 2000 V AC
Mechanical and thermal properties
Min. bending radius fixed installation: 4 x cable diameter
flexing up to 3m travel distance (horizontal, self supporting): 10 x cable diameter
flexing up to 10m travel distance (horizontal, sliding): 12 x cable diameter
Number of bending/ unbending
cycles 2 mio. cycles
Travel distance 10 m