Datasheet
1600203
DATA SHEET
valid from:
01.01.2019
Rubber Insulated Cable H05RR-F
Creator: KASC / PDC
Released: ALTE / PDC
Document: DB1600203EN
Version: 04
Page 1 of 1
We reserve all rights according to DIN ISO 16016.
PD 0019/05_04.18EN
Application
Rubber Insulated Cable H05RR-F is a tough rubber seated TRS cable for use on hand tools and light weight workshop tools subject to light to
medium stress in dry and damp conditions. Continuous, busy movements, usage of these cables in moving cable carriers, respectively on
motor drum guidance or under a strain of more than 15 N/mm² is not allowed.
Design
Design
acc. to HD 22.4 S4 that is VDE 0282 part 4
Certification
H05RR-F acc. to HD 22.4 S4 that is VDE 0282 part 4
Conductor
copper, fine wire strand in accordance to IEC 60228 that is VDE 0295,
class 5
Insulation
rubber compound EI4 in acc. to HD 22.1 that is VDE 0282 part 1
Core identification code
colour-coded in acc. to VDE 0293-1, HD 308 S2 that is VDE 0293-308
Outer sheath
rubber compound EM3 in acc. to HD 22.1, that is VDE 0282 part 1
colour: black
dlsafjlöj f
Electrical properties at 20°C
Rated voltage
300/500 V
Test voltage
2000 V AC
Mechanical and thermal properties
Minimum bending radius
for flexible use: 6 x cable diameter
Temperature range
for fixed installation and handling: -25 up to +60° C max. conductor temperature
Tests
acc. to VDE 0472 and IEC 60811-x.x that is VDE 0473
The cable is characterized with the ⊲HAR⊳ HAR-sign or HAR-identification thread.
General requirements
These cables are conform to the EU-Directive 2014/35/EU (Low Voltage Directive)