Datasheet

DATA SHEET
0162030
IEC compensating cable KN 41 L-SIL 2x0,5 oval
valid from :
01.12.2008
Originator: Frank Hörtnagl / PD-KL
Approved: Werner Körner / TE
Document: DB0162030EN page 1 of 1
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.
No.: 0019/0408
Application
The compensating cable KN 41 L-SIL 2 x 0,5 mm² is a silicone insulated cable which transmits the thermo-
electric voltage of NiCr/Ni thermocouples. It is for flexible use and fixed installation in dry rooms with low
mechanical load. They may only be installed outdoors with UV- and humidity protection and in observation of the
max. permitted temperature range.The steel wire armouring serves as mechanical protection.
Design
Conductor 0,5 mm² (16 x 0,20 mm)
Conductor material KCA alloying, accuracy class 2 according IEC 60584
Positive conductor: Fe (iron)
Negative conductor: CuNi (cupronickel)
Core insulation Silicone compound
Core identification Positive conductor: green
Negative conductor: white
Core layering Cores parallel next to each other
Outer sheath Silicone compound, colour: green
Armouring Galvanized steel wire braiding with interweaved green identification thread
Electrical properties
Limiting deviation class 2 ± 100 µV (± 2,5 °C) / m easuring point temperature +900 °C
Mechanical and thermal properties
Temperature range occasional flexing: -25 °C up t o +180 °C
Minimum bending radius occasional flexing: 15 x cable diameter
Flammability flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2