Data Sheet

DATA SHEET
2170005
RG 213 /U
valid from :
12. 06.2008
elaborated by:
TE-K: A. Khan / H. Pfeffer
Document: DB2170005EN page 1 of 1
Nr.: 0019/0894
Application
Coaxial cable for radio- and computer systems as well as the entire field of commercial radio-frequency tech-
nology and electronics. The low attenuation of this 50 Ohms coaxial cable allows high range transmissions.
Cable design and electrical properties of RG 213 /U according to MIL-C 17 F. Designation according to
MIL-C 17 F : M17/74-RG 213.
The cable is intended for limited flexible use and for static laying in dry and damp interiors and outdoor.
Design
Inner conductor stranded bare copper wires, 3.17 mm
2
, 7x 0.76mm, 2,25 ± 0,0254 mm
Insulation PE (polyethylene), 7,24 ± 0,178 mm
Outer conductor bare copper braid, coverage nom. 95 %
Sheath PVC, black, UV resistant, flame retardant
outer diameter 10.29 ± 0.18 mm
Electrical properties at 20°C
DC resistance inner
conductor
max./km
5.8
Insulation resistance
min. Gxkm
5
Capacitance at 1 kHz nom. nF/km
101
Nominal velocity of
propagation
%
66
Impedance
50 ± 2
Acc. to MIL 17/93G
Attenuation at 1 MHz dB/100m
nom. 0.6
5 MHz dB/100m
nom. 1.4
10 MHz dB/100m
nom. 2.0
20 MHz dB/100m
nom. 3.2
50 MHz dB/100m
nom. 4.5 max. 5.25
100 MHz dB/100m
nom. 7.0 max. 7.87
200 MHz dB/100m
nom. 10.2 max.11.45
400 MHz dB/100m
nom. 15.0 max. 15.75
600 MHz dB/100m
nom. 18.3
800 MHz dB/100m
nom. 23 max. 23
1 GHz dB/100m
nom. 27 max. 29.52
2 GHz dB/100m
nom. 40
HF voltage, peak value (not for power
purposes)
max.kV
5.0
Working voltage
(nominal voltage)
50 Hz U
eff
kV
5.0
Test voltage U
eff
kV
10
Mechanical and thermal properties
Weight approx. kg/km
150
Minimum bending radius fixed installation mm
55
repeated bending mm
150
Permissible temperature range fixed installation °C
- 40 bis + 80
moved °C
- 10 bis + 80
Fire load kWh/m
0.95
Flame propagation flame retardant acc. to IEC 60332-1-2
RoHS directive This cable confirms to RoHS directive (2002/95/EG)

Summary of content (1 pages)