Data Sheet

U.I. Lapp
GmbH
DATA SHEET
ETHERLINE
®
Cat. 5 ARM
DB2170496
valid from: 11.06.2012
Originator:
RAWE/
PDC
approved: HAPF/PDC
Document: DB2170496 page 1 of 1
All rights reserved acc. to DIN ISO 16016.
PD 0019/2.2_11.10DE
Application
ETHERLINE® Cat. 5 ARM is a CATEGORY 5 data cable for industrial usage. The screening ensures high transmission reliabil-
ity in areas with a high load of electromagnetic capacity and the armoring off two layers galvanized steel tape guarantees a
safe rodent protection.
Design
bare copper
-
wire
(AWG 22)
,
0.6
5 mm
conductor
Insulation
PE
, ca. 1
.
5
mm outer Ø
Core identification code
acc. to IEC 708
-
1
; white, yellow, blue, orange
Stranding
star quad
Wrapping
plastic tape
Inner sheath
PVC,
ca.
4.0
mm
Screening
plastic laminated aluminum foil
on top:
braid of copper wire, tinned wire, coverage ca. 85 %
Inner sheath
PVC, green, sheath thickness ca. 0.95 mm, outer
∅: ca. 6.5 mm
Armoring (rodent protection)
2 layers off galvanized steel tape, outer
∅: ca. 6.9 mm
Outer sheath
P
E
,
black
,
sheath
thickness ca. 1.2
mm,
oute
r
Ø
:
ca.
9.3
mm
Electrical properties at 20° C
Resistance (loop)
max.
12
4
Ω/km
Insulation resistance
min. 500
M
Ωxkm
Characteristic impedance
100
Ω ±
1
5
Ω
(
1MHz up to
100 MHz)
Signal propagation time
<
5
,
3
ns/m
Test voltage
(rms 50 Hz, 1 minute)
core/core:
20
00 V
core/screening: 2000 V
Transmission properties
f
[MHz]
Attenuation
max. [dB/100m]
NEXT
[dB/100m]
1 2.1 65.3
4 4.0 56.3
10 6.3 50.3
16 8.0 47.2
20 9.0 45.8
31.25 11.4 42.9
62.5 16.5 38.4
100 21.3 35.3
Electrical requirements acc. to EN 50288-2-1
Mechanical and thermal properties
Minimum bending radius
moved: 15 x
cable Ø
fixed installation: 10 x cable Ø
Permissible temperature range
moved:
-
20
˚ C up to +
6
0
˚ C
fixed installation: -40˚ C up to +70˚ C
General requirements
Dangerous and forbidden substances acc. to RoHS directive (2002/95/EG)
are not allowed to the manufacturing.