Data Sheet

U.I. Lapp
GmbH
DATASHEET
ÖLFLEX® CONTROL TM CY
281405CY
14.11.2013
PN 0486/01_03.10
Norm references / Approvals
Multi-standard cables have conductor strands with nominal sizes in mm² or AWG/kcmil. The master size is mentioned in the
table below, while the equivalent size of the other system can be found in the Appendix T16 of this catalogue. For this related
secondary size the cross-section of the conductor mostly works out to be greater than thespecified nominal value.
Cable type certifications UL MTW, TC-ER, WTTC 1000 V, BUS DROP, c(UL) Type TC, CIC FT4, CSA AWM I/II A/B FT4, UL
AWM style 20886
Product features
Flame-retardant according to CSA FT4 UL Vertical-Tray Flame Test
Oil-resistant according to UL OIL RES I & II
Water-resistant, UL Wet Approval 75 °C
High degree of screeninglow transfer impedance (max. 250 Ω/km at 30 MHz)
Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
Remark
Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon
request.
Copper price basis: EUR 150/100kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related
surcharges.
Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
Please specify the preferred type of packaging (e.g. 1 x 610 m drum or 8 x 76 m coils).
Photographs are not to scale and do not represent detailed images of the respective products.
*OD = Outer diameter
Technical Data
Number of cores and mm² per conductor: 5 G 2,5
Outer diameter (mm): 11,5
Copper index (kg/km): 160.3
Weight (kg/km): 268
Core identification code: Black with white numbers
Classification: ETIM 5.0 Class-ID: EC000104
ETIM 5.0 Class-Description: Control cable
Conductor stranding: Fine-wire, bare copper strand
Torsion movement in WTG: TW-0 & TW-2, refer to Appendix T0
Minimum bending radius: Static/Occ. moved: 5/20xOD*
Nominal voltage: UL/CSA: 600 V (TC, MTW, CIC), WTTC 1000 V
UL/CSA: 1000 V (AWM)
VDE U0 /U: 600/1000 V
Test voltage: 2000 V
Protective conductor: G = with GN-YE protective conductor
X = without protective conductor
Temperature range: -40°C (static)/ -25°C (occ. moved) to +90°C (AWM: +105°C)