Electrical properties at 20 °C
Rated voltage U
0
/ U IEC 600 / 1000 V
UL/ CSA 1000 V
Test voltage core/ core, core/ screen 4000 V AC
Specific insulation resistance > 20 G x cm
Surface transfer impedance at 30 MHz 250 / km
Mechanical and thermal properties
Min. bending radius occasional flexing: 15 x cable diameter
fixed installaion: 4 x cable diameter
Temperature range Part No. 0037000 up to 0037014 ÖLFLEX SERVO 9YSLCY-JB, TRANSPARENT
occasional flexing: IEC/ VDE -5 °C up to +80 °C max. conductor temp.
UL/ CSA -5 °C up to +80 °C max. conductor temp.
fixed installaion: IEC/ VDE -40 °C up to +80 °C max. conductor temp.
UL/ CSA -40 °C up to +80 °C max. conductor temp.
Temperature range Part No. 0036998, 0037015 up to 0037028 ÖLFLEX SERVO 9YSLCY-JB, BLACK
occasional flexing: IEC/ VDE -5 °C up to +90 °C max. conductor temp.
UL/ CSA -5 °C up to +80 °C max. conductor temp.
fixed installaion: IEC/ VDE -40 °C up to +90 °C max. conductor temp.
UL/ CSA -40 °C up to +80 °C max. conductor temp.
Flammability flame retardant in acc. with IEC 60332-1-2 resp. VDE 0482-332-1-2
UL: Vertical flame test VW-1
CSA: FT1
Tests acc. to IEC 60811 resp. VDE 0473, VDE 0472, EN 50395, EN 50396
EC Directives These cables are conform to the EC-Directives
2006/ 95/ EC (Low Voltage Directive) and
2011/ 65/ EU (RoHS, Restriction of the use of certain
hazardous substances).