Datasheet

4160100
DATA SHEET
valid from:
06.02.2019
Multi-Standard SC 2.1
Creator: PESA / PDC
Released: ALTE / PDC
Document: DB4160100EN
Version: 09
Page 1 of 1
We reserve all rights according to DIN ISO 16016.
PD 0019/05_04.18EN
Application
Multi-Standard SC 2.1 wiring cables are UL, CSA and HAR (VDE)* approved and are designed for use for control cabinet wiring as well as for
installation in protective tubes, applicable within the scope of the UL-, Canadian or European standard specifications. They are especially
qualified for wiring in industrial machines in accordance with NFPA 79.
At room temperature they are widely resistant to oils.
Application range:
HAR: wiring cable for internal wiring acc. to EN 50565-2 (VDE 0298-565-2)
UL (AWM): oil resistant wiring cable for internal wiring
UL (MTW): acc. to ANSI/NFPA 70 (National Electrical Code)
CSA (TEW): oil resistant wiring cable for internal wiring of devices
Design
H07V-K HAR (*) acc. to DIN EN 50525-2-31 / VDE 0285-525-2-31
UL (AWM) acc. to UL 758, Style 1015
UL (MTW) acc. to UL 1063, File-No. E198296
CSA (TEW) acc. to C22.2 No. 127-15
*For the dimensions 0.5; 0.75; 1.0 and16 mm² as well for the colours GN, YE, as for multi-coloured
cores (except for GN YE)
there are no HAR-approval available (X07V-K)!
fine-wired core of tinned copper strands acc. to IEC 60228 resp. VDE 0295, Class 5
special PVC-based compound
dlsafjlöj f
Electrical properties at 20°C
HAR H07-K U₀/U: 450 / 750 V AC
UL (AWM) / UL (MTW) / CSA (TEW) U: 600 V
2500 V AC
Mechanical and thermal properties
Minimum bending radius
fixed installation: OD≤8 mm: 4 x OD** / 2 x OD***
8<OD≤12 mm: 5 x OD** / 3 x OD***
OD>12 mm: 6 x OD** / 4 x OD***
** at conventional usage; *** at cautious bending
Temperature range
fixed installation:
HAR: -40 °C up to +70 °C max. conductor temp.
UL (MTW): up to +90 °C max. conductor temp.
UL (AWM): up to +105 °C max. conductor temp.
CSA (TEW): up to +105 °C max. conductor temp.
Flammability
HAR: IEC 60332-1-2 resp. VDE 0482-332-1-2
UL: VW-1
CSA: FT1
Oil resistance
UL/CSA: 60°C oil rating
Tests
acc. to IEC 60811 resp. VDE 0473-811, EN 50395, UL 1581, UL 1063 and CSA C22.2
General requirements
These cables are conform to the EU-Directive 2014/35/EU (Low Voltage Directive)

Summary of content (1 pages)