Datasheet

DATA SHEET
0028110
ÖLFLEX
®
ROBOT 900 P
valid from :
21.07.2008
created by: R. Krämer / TE-K
released: M. Herb / TE-K
Document: DB0028110EN page 1 of 1
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.
No.: 0016/0894
Application
ÖLFLEX
®
ROBOT 900 P is a special cable for torsion and bending stresses, e.g. for connecting handling tools to
assembly and welding robots, to manipulators as well as for connecting to rotating or tilting tables. They can be
used for the transmission of control and monitoring signals or as supply cables. They are among others for use in
dry, damp or wet rooms. They may only be installed outdoors in observation of the appropriate temperature
range. Usage on motor drum guidance or under a strain of more than 15 N / mm² is not allowed.
ÖLFLEX
®
ROBOT 900 P cables are increased oil resistant and at room temperature generally resistant against
acids and caustic solutions. The outer sheath of Polyurethane is resistant against high mechanical load, particu-
larly to abrasion and scouring, cut resistant, microbe-proof and hydrolysis resistant.
Design
Design in support to HD 21.5 S3 resp. VDE 0281-5,
in support to HD 21.13 S1 resp. VDE 0281-13, VDE 0812
Conductor fine or superfine wire strands of bare copper
acc. to IEC 60228 resp. VDE 0295, class 5 or class 6
Core insulation TPE (Thermoplastic Elastomer)
Core identification up to 0,34 mm
2
: in acc. to DIN 47100
starting at 0,50 mm
2
:acc. to VDE 0293-1, with or without gn/ye ground conductor
black cores with white numbers
acc. to DIN EN 50334 resp. VDE 0293 part 334
Outer sheath Polyurethane compound TMPU acc. to HD 22.10 S2 resp. VDE 0282-10,
additional flame retardant
Electrical properties at 20 °C
Nominal voltage up to 0,34 mm
2
: 48 V AC
starting at 0,50 mm
2
:300 / 500 V
Peak working voltage up to 0,34 mm
2
: 350 V (not for high-power current purposes)
Test voltage up to 0,34 mm
2
: 1500 V AC
starting at 0,50 mm
2
:3000 V AC
Mechanical and thermal properties
Temperature range for flex. applications -40 °C up to +80 °C max. conductor temperature
fixed installation -50 °C up to +80 °C max. conductor temperature
Max. angle of torsion +/- 360 °/ meter
Min. bending radius 4 x cable diameter for fixed installation
15 x cable diameter for flex. applications
Flammability flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2
Oil resistance acc. to IEC 60811-2-1 resp. VDE 0473 part 811-2-1
Tests acc. to IEC 60811-x-x resp. VDE 0473 part 811-x-x and VDE 0472
EC directive this cable confirms to ECD 2006/95/EC (low voltage directive).