Datasheet

DATA SHEET
0152015
DIN compensating cable KN 11 L-SIL-S 2x1,5
valid from :
01.12.2008
Originator: Frank Hörtnagl / PD-KL
Approved: Werner Körner / TE
Document: DB0152015EN page 1 of 1
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.
No.: 0019/0408
Application
The compensating cable KN 11 L-SIL-S 2 x 1,5 mm² is a silicone and glass fibre insulated cable which transmits
the thermoelectric voltage of NiCr/Ni thermocouples. It is for flexible use and fixed installation in dry rooms with
medium mechanical load. It may only be installed outdoors with UV- and humidity protection and in observation
of the max. permitted temperature range.The steel wire armouring serves as mechanical protection.
Design
Conductor 1,5 mm² (48 x 0,20 mm)
Conductor material KCA alloying, accuracy class 2 according DIN 43722
Positive conductor: Fe (iron)
Negative conductor: CuNi (cupronickel)
Core insulation Silicone compound
Core identification Positive conductor: red
Negative conductor: green
Core layering Cores twisted together
Outer sheath Glass fibre braiding with interweaved green identification thread
Armouring Galvanized steel wire braiding with interweaved green identification thread
Electrical properties
Limiting deviation class 2 ± 100 µV (± 2,5 °C) / m easuring point temperature +900 °C
Mechanical and thermal properties
Temperature range occasional flexing: -25 °C up t o +180 °C
Minimum bending radius occasional flexing: 15 x cable diameter
Flammability flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2