Datasheet

DATA SHEET
0161011
IEC extension cable KE 9 L-S 2x1,5
valid from :
01.12.2008
Originator: Frank Hörtnagl / PD-KL
Approved: Werner Körner / TE
Document: DB0161011EN page 1 of 1
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.
No.: 0019/0408
Application
The extension cable KE 9 L-S 2 x 1,5 mis a PVC insulated cable which transmits the thermoelectric voltage
of Fe/CuNi thermocouples. It is for flexible use and fixed installation in dry rooms with medium mechanical load.
They may only be installed outdoors with UV- and humidity protection and in observation of the max. permitted
temperature range.The steel wire armouring serves as mechanical protection.
Design
Conductor 1,5 mm² (48 x 0,20 mm)
Conductor material JX alloying, accuracy class 2 according IEC 60584
Positive conductor: Fe (iron)
Negative conductor: CuNi (cupronickel)
Core insulation PVC compound
Core identification Positive conductor: black
Negative conductor: white
Core layering Cores twisted together
Outer sheath PVC compound, colour: black
Armouring Galvanized steel wire braiding with interweaved black identification thread
Electrical properties
Limiting deviation class 2 ± 140 µV (± 2,5 °C) / m easuring point temperature +500 °C
Mechanical and thermal properties
Temperature range occasional flexing: -5 °C up to +70 °C
Minimum bending radius occasional flexing: 15 x cable diameter
Flammability flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2

Summary of content (1 pages)