Datasheet

DATA SHEET
0162006
IEC compensating cable KN 4 L-S 2x1,5 oval
valid from :
01.12.2008
Originator: Frank Hörtnagl / PD-KL
Approved: Werner Körner / TE
Document: DB0162006EN page 1 of 1
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.
No.: 0019/0408
Application
The compensating cable KN 4 L-S 2 x 1,5 mm² is a glass fibre insulated cable which transmits the thermoelectric
voltage of NiCr/Ni thermocouples. It is for fixed installation in dry rooms and may only be installed outdoors with
UV- and humidity protection and in observation of the max. permitted temperature range. The steel wire
armouring serves as mechanical protection.
Design
Conductor 1,5 mm² (48 x 0,20 mm)
Conductor material KCA alloying, accuracy class 2 according IEC 60584
Positive conductor: Fe (iron)
Negative conductor: CuNi (cupronickel)
Core insulation Glass fibre covering
Core identification Positive conductor: green marked
Negative conductor: white marked
Core layering Cores parallel next to each other
Outer sheath Glass fibre braiding with interweaved green identification thread
Armouring Galvanized steel wire braiding with interweaved green identification thread
Electrical properties
Limiting deviation class 2 ± 100 µV (± 2,5 °C) / m easuring point temperature +900 °C
Mechanical and thermal properties
Temperature range occasional flexing: -25 °C up t o +200 °C
Minimum bending radius occasional flexing: 15 x cable diameter
Flammability flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2