Datasheet

DATA SHEET
0164012
IEC compensating cable KN 20 L 2x1,5
valid from :
01.12.2008
Originator: Frank Hörtnagl / PD-KL
Approved: Werner Körner / TE
Document: DB0164012EN page 1 of 1
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.
No.: 0019/0408
Application
The compensating cable KN 20 L 2 x 1,5 mm² is a PVC insulated cable with aluminium foil screen which
transmits the thermoelectric voltage of NiCr/Ni thermocouples. It is for flexible use and fixed installation in dry and
damp rooms with medium mechanical load. They may only be installed outdoors with UV protection and in
observation of the max. permitted temperature range. The overlapping foil wrapping screens the cores against
electromagnetical interference.
Design
Conductor 1,5 mm² (48 x 0,20 mm)
Conductor material KCA alloying, accuracy class 2 according IEC 60584
Positive conductor: Fe (iron)
Negative conductor: CuNi (cupronickel)
Core insulation PVC compound
Core identification Positive conductor: green
Negative conductor: white
Core layering Cores twisted together
Screening aluminium cladded plastic foil with tinned copper drain wire (7x0,30 mm)
Outer sheath PVC compound, colour: green
Electrical properties
Limiting deviation class 2 ± 100 µV (± 2,5 °C) / m easuring point temperature +900 °C
Mechanical and thermal properties
Temperature range occasional flexing: -5 °C up to +70 °C
Minimum bending radius occasional flexing: 15 x cable diameter
Flammability flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2