Datasheet

U.I. Lapp
GmbH
DATA SHEET
ÖLFLEX
®
CHAIN 808 CP
DB 1027751
valid from: 2014-02-21
Originator: KASC / PDC
approved: HAPF / PDC
Document: DB00127751EN
All rights reserved acc. to DIN ISO 16016.
PD 0019/2.2_11.10EN
Application
ÖLFLEX
CHAIN 808 CP cables are high-flexible oil-resistant power and control cables with an outer sheath of Polyurethane
for flexible use and fixed installation under light or medium mechanical load conditions. They are among others designed for
use in dry, damp or wet rooms. Considering the indicated temperature range an outdoor use is possible. ÖLFLEX
CHAIN
808 CP cables are increased oil resistant and at room temperature widely resistant to acids and caustic solutions. The outer
sheath is resistant to high mechanical load, particularly to abrasion and scouring, cut resistant, microbe-proof and hydrolysis
resistant. They are especially suitable for basic requirements (Basic Line) in power chains and in permanently moved ma-
chine parts. Usage of these cables in moving cable carriers or on motor drum guidance or under a tensile strain of more
than 15 N/mm
2
conductor cross-section is not allowed. The screen is a protection against electrical interference.
Application range:
Power chains or moving machine parts, especially in wet areas of machine tools and transfer lines, measuring, control
and regulation circuits.
Design
Design based on
DIN EN 50525-2-21 resp. VDE 0285-525-2-21 and
DIN EN 50525.2.51 resp. VDE 0285-525-2-51
Conductor fine wire strands of bare copper acc. to IEC 60228 resp. VDE 0295, Class 5
Core insulation LAPP special PVC compound P8/1, better than the PVC compound TI2
acc. to DIN EN 50363-3 resp. VDE 0207-363-3
Core identification acc. to VDE 0293-1, with or without GN/YE protective conductor
black cores with white numbers
acc. to DIN EN 50334 resp. VDE 0293-334
Taping non-woven wrapping
Screen braid of tinned copper wires, coverage = 85% (nominal value)
Outer sheath Polyurethane compound TMPU acc. to EN 50363-10-2 resp. VDE 0207-363-10-2
Colour: grey, similar RAL 7001
Electrical properties
Nominal voltage U
0
/U: 300/500 V
Test voltage Core/Core: 4000 V AC
Core/Screen: 2000 V AC
Mechanical and thermal properties
Min. bending radius flexing up to 3m travel distance (horizontal, self supporting): 10 x cable diameter
flexing up to 10m travel distance (horizontal, sliding): 12 x cable diameter
fixed installation: 4 x cable diameter
Number of bending/unbending
cycles 2 mio. cycles
Travel distance 10 m
Temperature range flexing: -5 °C up to +70 °C max. conductor temp.
fixed installation: -40 °C up to +80 °C max. conductor temp.
Oil resistance acc. to EN 50363-10-2 resp. VDE 0207-363-10-2
Tests acc. to IEC 60811 resp. VDE 0473 part 811, EN 50395, EN 50396
EC Directives This cable is conform to the EC-Directives 2006/95/EC (Low Voltage Directive)
and 2002/95/EC (RoHS, Restriction of the use of certain hazardous substances).

Summary of content (1 pages)