DATA SHEET
1123000
ÖLFLEX
®
CLASSIC 130 H
valid from :
20.03.2008
elaborated by:
TE-K: M. Herb / R. Krämer
Document: DB1123000EN
Page 1 von 1
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.
No.: 0016/0894
Application
ÖLFLEX CLASSIC 130 H are halogen free, flame retardant control cables for flexible use and fixed installation for
normal mechanical use. They are among others for use in dry and damp rooms. They may only be installed
outdoors with UV-protection and in observation of the appropriate temperature range. They are not for use in
non-continuously recurring movement. Continuous, busy movements, movements forced by the guide, usage of
these cables in moving cable carriers or on motor drum guidance or under a strain of more than 15 N/mm² is not
allowed.
ÖLFLEX
®
CLASSIC 130 H can be used in public facilities, airports, railway stations, plants engineering and
constructions, air conditioning systems and particularly where human and animal life as well as valuable property
are exposed to high risk of fire hazards.
Design
Design acc. to HD 21.14 S1 resp. VDE 0281 part 14
Conductor fine wire strands of bare copper, acc. to IEC 60228 resp. VDE 0295, class 5
Core insulation halogen free compound TI6 acc. to HD 21.14 S1 resp. VDE 0281 part 14
Core identification acc. to VDE 0293-1, with or without gn/ye ground conductor
black cores with white numbers
acc. to DIN EN 50334 resp. VDE 0293 part 334
Outer sheath halogen free compound TM7 acc. to HD 21.14 S1 resp. VDE 0281 part14
colour: silver grey
Electrical properties at 20 °C
Nominal voltage 300 / 500 V
Test voltage 4000 V AC
Mechanical and thermal properties
Temperature range for flex. applications -15 °C to +70 °C max. conductor temperature
fixed installation -40 °C to +70 °C max. conductor temperature
Min. bending radius 4 x cable diameter for fixed installation
15 x cable diameter for flex. applications
Flammability flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2
flame retardant in acc. to IEC 60332-3-24 (Cat. C) resp. VDE 0482-266-2-4
Smoke density acc. to IEC 61034-2
Toxicity acc. to NES 713 part 3
Halogen-free acc. to IEC 60754-1 resp. VDE 0472 part 815
Corrosivity acc. to IEC 60754-2 resp. VDE 0482 part 267-2-3
Tests acc. to IEC 60811-x-x resp. VDE 0473 part 811-x-x and VDE 0472
EC directive this cable confirms to ECD 2006/95/EC (low voltage directive).