Application
ÖLFLEX CLASSIC 135 CH are screened, halogen free, highly flame retardant control cables for the European and North
American market, for occasional flexible use and fixed installation subject to normal mechanical load conditions. They are
among others for use in dry, humid or wet conditions. Considering the temperature range, a temporary outdoor use is possi-
ble. They are suitable for non-continuously recurring movement without tensile load. Continuous operational movements,
restricted guidance, usage of these cables in moving cable carriers or on motor drum guidance or under a strain of more
than 15 N/mm² is not allowed. The screen is a protection against electrical interference.
Application range:
ÖLFLEX
®
CLASSIC 135 CH can be used in public buildings, airports, railway stations, plants engineering and constructions,
air conditioning systems and particularly where human and animal life as well as valuable property are exposed to high risk
of fire hazards.
USE acc. to: FRPE sheathed cable for internal wiring of appliances and external interconnection of electronic
equipment
Design
Design acc. to UL AWM 758, Style 21089 and
based on EN 50525-3-11 resp. VDE 0285-525-3-11
Approval UL AWM 758, Style 21089 (File No. E63634)
Conductor fine wire strands of bare copper, acc. to IEC 60228 resp. VDE 0295, Class 5
Core insulation halogen free compound TI6 acc. to
EN 50363-7 resp. VDE 0207-363-7
Core identification acc. to VDE 0293-1, with or without GN/YE ground conductor
black cores with white numbers acc. to DIN EN 50334 resp. VDE 0293-334
Screen braid of tinned copper, coverage = 85% (nominal value)
Outer sheath halogen free compound TM7 acc. to EN 50363-8 resp. VDE 0207-363-8
colour: silver grey, similar RAL 7001
Electrical properties
Nominal voltage VDE U
0
/U: 300 / 500 V
UL: 600 V
Test voltage Core / Core: 4000 V
Core / Screen: 2000 V
Mechanical and thermal properties
Min. bending radius occasional flexing: 20 x outer diameter
fixed installation: 6 x outer diameter
Temperature range occasional flexing (VDE): -15 °C up to +70 °C max. conductor temp.
occasional flexing (UL): -15 °C up to +75 °C max. conductor temp.
fixed installation (VDE): -40 °C up to +80 °C max. conductor temp.
fixed installation (UL): -40 °C up to +75 °C max. conductor temp.