Application
ÖLFLEX
®
CLASSIC 130 H BK 0,6/1 kV are halogen free, flame retardant control cables for occasional flexible use and fixed
installation subject to normal mechanical load conditions. They are among others designed for use in dry and humid rooms.
Outdoor use: They may only be installed considering the indicated temperature range. They are not for use in continuously
recurring movement. Continuous movement, usage of these cables in moving cable carriers or on motor drum guidance or
under a tensile strain of more than 15 N/mm² conductor cross-section is not allowed.
Application range:
Public buildings, airports, railway stations, plant engineering, industrial machinery, heating and air-conditioning systems and
particularly where human and animal life as well as valuable property are exposed to high risk of fire hazards.
Design
Design based on HD 21.14 S1/ VDE 0281-14, EN 50525-3-11/VDE 0285-525-3-11
Conductor fine wire strands of bare copper, acc. to IEC 60228 resp. VDE 0295, Class 5
Core insulation halogen free compound TI6 acc. to HD 21.14 S1/ VDE 0281-14,
EN 50525-3-11/VDE 0285-525-3-11
Core identification acc. to VDE 0293-1, with or without GN/YE protective conductor
up to 5 cores coloured in acc. to HD 308 S2 that is VDE 0293-308
starting at 6 cores: Black cores with white numbers
acc. to DIN EN 50334 resp. VDE 0293-334
Outer sheath halogen free compound TM7 acc. to HD 21.14 S1/ VDE 0281-14,
EN 50525-3-11/VDE 0285-525-3-11
colour: Black
Electrical properties at 20 °C
Nominal voltage U
0
/U: 600 / 1000 V
Test voltage 4000 V AC
Mechanical and thermal properties
Min. bending radius occasional flexing: 15 x cable diameter
fixed installation: 4 x cable diameter
Temperature range occasional flexing: -15 °C up to +70 °C max. conductor temperature
fixed installation: -40 °C up to +80 °C max. conductor temperature
Flammability flame retardant in acc. with IEC 60332-1-2 resp. VDE 0482-332-1-2
no flame propagation
in acc. with IEC 60332-3-24 resp. EN 50266-2-4 resp. VDE 0482 part 266-2-4 or
in acc. with IEC 60332-3-25 resp. EN 50266-2-5 resp. VDE 0482 part 266-2-5
Smoke density acc. to IEC 61034-2
Toxicity acc. to NES 713 part 3
Halogen-free acc. to IEC 60754-1
Corrosivity acc. to IEC 60754-2
UV resistance UV and weather-resistant acc. to ISO 4892-2
Ozone resistance Ozone-resistant acc. to EN 50396
Tests acc. to IEC 60811, EN 50395, EN 50396
EC Directives This cable is conform to the EC-Directives 2006/95/EC (Low Voltage Directive)
and 2002/95/EC (RoHS, Restriction of the use of certain hazardous substances).