Datasheet

DATA SHEET
7072400
LK SMS
INX
Servo Cables acc to Indramat
1)
Standard INK
1)
Valid up from :
May.3
th
. 2012
Elaborated from:
PD-KL – A. Turan
Rev. VoHu1, 12.06.2008
VoHu1, 08.08,2011
VoHu1, 03.05.2012
Document: DB7072400EN_4 Page 1 of 3
Nr.:
Application
LAPP servo cables according to Indramat
1)
Standard INK
1)
are highly flexible screened servo drive cables (Art-Nr:
7072403 to 7072412 & 7072417), and encoder and resolver cables (Art-Nr: 7072400 to 7072402 and 7072414 up
to 7072416), with PUR outer sheath and UL/CSA AWM approvals. They are suitable for highly flexible use in
power chains and also for static use. These cables are generally used for the interconnection between frequency
converters and servo drives. Typical kind of application: in machine tools, production plants, car body presses,
transfer lines... Those cables can be used in dry and damp areas and also outdoor provided the recommended
temperatures of use are respected. Usage of these cables in moving cable carriers, respectively on motor drum
guidance or under a strain of more than 15 N/mm2 is not allowed. SERVO LK INX cables are increased oil-
resistant, halogen-free and free of lacquer destructive substances.
Technical Data
Conductor Bare copper, extra fine wire stranding in acc. to IEC 60228 Class 6.
Core insulation TPE-E compound (Motor and servo cables)
PP / TPE compound (Resolver and encoder cables)
Core Identification Servomotor cables:
Power: Black cores with white printing (1,2,3) and GNYE protective conductor
Control cores: black with white printing 5-6 and 7-8
Core Identification Signal cables: see additional P/N -individual information of that data sheet
Overall screening All cables having braids, made of tinned copper wires, optical coverage > 80%
Outer sheath PUR compound TMPU in acc. to HD 22.10 S1, flame retardant, oil-resistant acc. to
VDE 0473-811-2-1, colour Orange (RAL 2003)
Rated Voltage Power cable: Signal cables:
Power cores: 600/1000 V (IEC) 300/300 V (IEC)
1000 V (UL) 300 V (UL/CSA)
Control cores: 250 V AC (IEC)
1000 V (UL/CSA)
Test voltage Power cables: 4kV (control cores: 2kV)
Signal cables: 500 V
Temp. range Flexible use: -30°C up to +80°C max. conductor temperature
Static use: -50°C up to +80°C max. conductor temperature
Min. bending radius for flexible use in non-supported power chains: 7,5 x outer diameter
(below 70°C)
for flexible use in horizontal operating chains, where the upper part is gliding on top
of the lower part: 10 x outer diameter
For static use: 5 x outer diameter
Oil resistance acc. to DINEN 60 811-2-1 (VDE 0473-811-2-1)
Flame retardant vertical flame test in acc. to UL1581§1061 FT1, IEC60332.1-2
Approvals Power cables: UL AWM Style 20234, CSA AWM I/II A/B
Signal cables: UL AWM Style 20236, CSA AWM I/II A/B