User's Manual

MXiV DUAL PALLET OPERATIONS AND MAINTENANCE
Figure 7 Main Menu
2.3 BEFORE TURNING THE AMPLIFIER ON
From the Main Menu, the status of the amplifier is displayed and shows if the amplifier is ready for operation.
Status legends, when lit, such as the INTK (INTERLOCK), usually signify OK conditions and that the transmitter is
ready to be turned ON.
Check that all of the following conditions are met:
1. EXCITER or Channel Processor is Ready.
Usually in the application of AC, the Exciter goes through its warm-up sequence. Ensure that it
has done so.
2. POWER METERING is at Zero.
On the LCD (see Main Menu display in
Figure 7), the PWR should be at 000% and the STATUS
should be TX IS OFF, NORMALLY.
3. MXi CONTROLLER is ready.
If there were prior faults, clear them by pushing the RESET button.
4. INTERLOCKS are closed or OK.
Interlocks and Status are OK.
Figure 8 Interlocks Status
5. AGC control is DISABLED at this time.
Push the AGC button on the touchpad so that it is NOT selected.
Figure 9 AGC OFF
6. The Amplifier is in LOCAL mode.
Push the REM button so that it is NOT lit.
7. The TX is OFF.
TSM21Q-365 Rev 0 July 17, 2009 MXiV Dual Pallet Operations and Maintenance 15