User Manual

MXi AMPLIFIER CONTROLLER BOARD REV.2
PUB06-82 Rev 1 July 17, 2007 06-82-25 MXi Amplifier Controller Board Rev.2
Figure 15 Logs Submenu Screen
The logs are displayed up to three at a time, in the order in which they were detected in the controller. That is, the
logs are in chronological order from the time they were received. The seventh menu button on the fourth line of
the LCD shows the total number of log entries [our example shows 2 entries #=02].
A maximum of 99 log entries can be held in the log table. If the log table already contains 99 entries and a new
log has occurred, the oldest log is discarded and the new log is entered into the table. In this manner the log table
will hold the 99 most recent logs.
In the fourth menu button line of the LCD, the first four button selections (from the left side) allow the operator to
navigate through the log table when there are more than three logs. If there are three logs or less, all the entries
are already displayed on the LCD.
The first menu button is labeled 1
ST
and causes the display to return to the beginning of the log table and display
the first three entries.
The second menu button is labeled LAST and causes the display to jump to the end of the log table and display
the last three entries.
The third menu button is labeled NEXT and causes the display to scroll down one log entry. If the LCD was
displaying LOGS 2-4, then pressing NEXT displays LOGS 3-5.
The fourth menu button is labeled 1
ST
and causes the display to scroll down up one log entry. If the LCD was
displaying LOGS 2-4, then pressing PREV displays LOGS 1-3.
The fifth menu button is labeled CLR and causes the log table to be cleared and the LCD will have no logs to
display and the count will revert back to zero #=00. As noted previously, the log count is located in the seventh
menu button position. Pressing this button does not perform any function.
The eighth menu button is labeled OUT and causes the LCD screen to return to the Main Menu.
3.6 GENERAL SCREEN
The General submenu is entered by pressing the GEN submenu button on the main LCD screen.
This submenu displays all the configuration and setup information of the particular model of MXi transmitter. The
first line displays the transmitter type, the second line displays the software code and revision, the third line
displays the LARCAN ID number that is used in the factory to determine options, date the boards were made and
other information. This information is not really important for day to day operations but can be useful when dealing
with LARCAN service in verifying the transmitter configuration.
There is only one menu button option on the fourth line of the LCD screen, which is the OUT button in the eighth
position. Pressing this button causes the LCD screen to return to the Main Menu.
The LCD displays a typical GEN submenu as follows: